Time: Jul., 2024
Place: Wuxi, Jiangsu Province
Capacity: 40m³/h
Membrane operating flow: 60m³/h
Membrane type: Tubular UF Membrane~HWM-TUF30-63E
Membrane QTY: 15pcs
Application:Grinding Wastewater for Semiconductor Industry
Introduction:
JCET Group Grinding Wastewater Treatment Projerct
The tubular UF system reconstructed by HOWIE membrane in Jul., 2024,
Process: Grinding wastewater→circulating concentration tank→pipeline filter→tubular UF membrane→produced water reuse, the concentrate flocculated with chemicals and filtered by plate-frame filtration, the sludge outward transport.
There are 3sets of tubular UF system on site, 5pcs 6inch 3meter tubular membrane modul per set, single module membrane area is 15.2㎡,designed recovery rate >90%, required permeate turbidity<1NTU.

Operating data:
Inlet Water | Inlet water flow m³/h | Operating pressure MPa | Operating pressure m³/h | Permeate flow m³/h | Permeate turbidity NTU |
Circulation concentration tank | 80 | 0.41 | 160 | 23 | 0.25 |